内容标题4

  • <tr id='5246Uw'><strong id='5246Uw'></strong><small id='5246Uw'></small><button id='5246Uw'></button><li id='5246Uw'><noscript id='5246Uw'><big id='5246Uw'></big><dt id='5246Uw'></dt></noscript></li></tr><ol id='5246Uw'><option id='5246Uw'><table id='5246Uw'><blockquote id='5246Uw'><tbody id='5246Uw'></tbody></blockquote></table></option></ol><u id='5246Uw'></u><kbd id='5246Uw'><kbd id='5246Uw'></kbd></kbd>

    <code id='5246Uw'><strong id='5246Uw'></strong></code>

    <fieldset id='5246Uw'></fieldset>
          <span id='5246Uw'></span>

              <ins id='5246Uw'></ins>
              <acronym id='5246Uw'><em id='5246Uw'></em><td id='5246Uw'><div id='5246Uw'></div></td></acronym><address id='5246Uw'><big id='5246Uw'><big id='5246Uw'></big><legend id='5246Uw'></legend></big></address>

              <i id='5246Uw'><div id='5246Uw'><ins id='5246Uw'></ins></div></i>
              <i id='5246Uw'></i>
            1. <dl id='5246Uw'></dl>
              1. <blockquote id='5246Uw'><q id='5246Uw'><noscript id='5246Uw'></noscript><dt id='5246Uw'></dt></q></blockquote><noframes id='5246Uw'><i id='5246Uw'></i>

                深圳证券交易所

                股票代码:002819

                股票代码

                SZ002819

                400-650-5566
                主机 分类索引
                产品中心

                BRUKER S8 TIGER Series 2 X射线荧光光该不会是留下后遗症吧谱仪

                bruker S8 TIGER Series 2 X射线荧宝马车从他们光光谱仪

                BRUKER S8 TIGER Series 2 X射线荧光妖兽光谱仪 Overview


                S8 TIGER Series 2

                Thanks to HighSense technology the S8 TIGER Series 2 WDXRF spectrometer delivers for all elements accuracy and precision for industrial quality and process control.

                With high resolving WDXRF technology and optimal detection of light, medium and heavy elements based on the new HighSense beam path, the XRF2 mapping tool of the S8 TIGER Series delivers best sensitivity, smallest spot size, and highest resolution for small spot applications.

                Ergonomic and failsafe operation are vital for efficiency and best analytical data. Simple, intuitive start of samples are guaranteed with the multilingual TouchControl interface.

                HighSense Technology
                S8 TIGER with HighSense

                The S8 TIGER Series 2 comes with the revolutionary HighSense? technologyfor WDXRF. It offers an exceptional linear dynamic range enabling higher precision levels for process and quality control in cement, minerals, mining, metals, glass, and ceramics.


                XRF2 Small spot mapping
                S8 TIGER with XRF2 Small spot mapping

                The S8 TIGER Series 2 features XRF2 small spot mapping which provides detailed maps of the elemental distribution in materials. With a 300μm spot size, XRF2 offers the highest resolution available in a WDXRF instrument.


                EZ Ergo - Easy Operation
                S8 TIGER with EZ Ergo

                The S8 TIGER Series 2 comes with intuitive and failsafe operation based on the new multilingual TouchControl interface. With EasyLoad it is designed for high sample throughput. Optimal instrument uptime and low cost of operation are ensured with the unique SampleCare feature - simply EZ Ergo.



                BRUKER S8 TIGER Series 2 X射线荧光光谱仪 Technical Details


                SystemsS8 TIGER 1 kW
                1kW
                50 kV max.
                50 mA max.
                S8 TIGER 3 kW
                3 kW
                60 kV max.
                150 mA max.
                S8 TIGER 4 kW
                4 kW
                60 kV max.
                170 mA max.
                X-ray tubesRh, 75 μm Be WindowRh, 75 μm Be Window
                Rh, 50 μm Be Window, SampleCare protective coating
                Rh, 28 μm Be Window, SampleCare protective coating
                Cr, max.3.3 kW
                Rh, 75 μm Be Window
                Rh, 50 μm Be Window, SampleCare protective coating
                Rh, 28 μm Be Window, SampleCare protective coating
                Cr, max.3.3 kW
                CollimatorAutomatic collimator changer (up to 4)
                Analyzer crystalsAutomatic crystal changer (up to 8)
                Included: XS-55, PET, LiF (200)
                Optional: XS-B, XS-C, XS-N, XS-PET-C, XS-CEM, XS-Ge-C, LiF (220), LiF (420), ADP, Ge, TlAP, InSb, XS-N-HS, XS-100, XS-400, XS-InSb-C
                DynaMatch?Linear intensity range more than 13 million cps
                HighSense DetectorsProportional flow counter and Scintillation Counter: Capacity more than 3 Mio cps, 2 Mio cps linear range
                XRF2High Resolution and high Intensity Element Mapping with 0.3 mm and 1.25 mm spot (FWHM)
                Automated Mask ChangerAutomatic masks : closed (SampleCare;) 34 mm, 28 mm, 23 mm, 18 mm, 8 mm (BeamGuide), 5 mm (BeamGuide)
                TouchControl? 1)Integrated touchscreen for easy and intuitive operation
                SampleCare? 1)X-ray tube and goniometer protected by contamination shields
                Sample and spectrometer chamber separated by programmable vacuum seal
                EasyLoad? 1)Automatic sample recognition
                Portable sample trays
                Power requirements208 – 240 V (1P/3P)
                50/60 Hz
                208 V, 60 Hz (1P/3P)
                230 V, 50/60 Hz (3P)
                Compressed airNot required
                Detector gasP5 gas (5% methane, 95% argon) for flow counter
                P10 gas (10% methane, 90% argon) for flow counter
                External cooling waterNo cooling waterCooling water
                Water consumption automatically regulated and minimized, short term interruptions are compensated
                Dimensions
                (height x width x depth)
                135 cm x 84 cm x 90 cm;
                53.1” x 33.1” x 35.4”
                135 cm x 84 cm x 104 cm;
                53.1” x 33.1” x 41”
                Touchscreen: Allows additional width of 49 cm (19.3’’)
                446 kg476 kg
                Quality & safetyDIN EN ISO 9001:2008
                CE certified
                Fully radiation protected system; radiation < 1 μSv/h (BfS 09/07 V R?V)